Detalhes do produto:
|
| Tipo: | Tanque de água de armazenamento | Classe de precisão: | Precisão padrão |
|---|---|---|---|
| Precisão: | Dentro de ±15% | Aplicativo: | PV |
| Suporte personalizado: | OEM, ODM | Poder: | 220 V 50 Hz |
| Classe de Proteção: | / | Tensão: | Equipamento Elétrico 220V |
| Garantia: | 1 ano | Dimensão Interna: | 700*700*1200 mm |
| Dimensão externa: | 1000*1000*1320mm | Tamanho da amostra máximo: | 300*400*100mm |
| Método de levantamento de amostra: | Equipar talha elétrica para transportar amostra para cima e para baixo | Peso da amostra: | Máximo até 100kg |
| Poder: | Monofásico, 220V 50Hz | padrão de teste: | CEI 60529 - IPX7 |
| Operating Modes | Standby, stop, constant-current (CC) charging/discharging, constant-voltage (CV) charging/discharging, constant-power (CP) charging/discharging, constant-current/constant-voltage (CC/CV) charging/discharging |
|---|---|
| Cut-off Conditions | Voltage, current, time, capacity |
| Input Voltage (High-Voltage Side) | 650Vdc to 720Vdc |
|---|---|
| Input Reverse Polarity Protection | Provided |
| Output Voltage (Low-Voltage Side) | 0Vdc to 5Vdc (Adjustable) |
| Voltage Accuracy (Cell Side) | ±0.02%FS @ 25±5℃ |
| Charging Current | 450mA to 1,200,000mA |
| Current Accuracy (Cell Side) | ±0.04%FS @ 25±5℃ |
| Charging Efficiency | Peak efficiency > 92% |
| Input Voltage (Low-Voltage Side) | 0.5Vdc to 5Vdc, Terminal Voltage |
|---|---|
| Voltage Accuracy (Cell Side) | ±0.02%FS @ 25±5℃ |
| Current Range | 120mA to 450,000mA |
| Current Accuracy (Cell Side) | ±0.04%FS @ 25±5℃ |
| Output Voltage (High-Voltage Side) | 640Vdc to 750Vdc |
| Maximum Output Current | 1,200,000mA |
| Discharging Efficiency | Peak efficiency > 90% |
| Response Time | Current response time 10%~90%FS: < 10ms Charge/discharge current switching time 90%~+90%FS: < 20ms |
|---|---|
| Current Overshoot | < 5%FS 0.5m (with 0.5m power cable length) |
| Ripple | < 1%FS |
| Protection Systems | Over-voltage, under-voltage, over-current, output short-circuit, over-temperature, battery reverse-connection, communication loss, sampling abnormality, power-side fuse protection |
| Negative Voltage Acquisition | Capable of directly acquiring true negative voltage |
| Auxiliary Voltage | Provides auxiliary voltage sampling with accuracy less than 2mV |
| Data Reporting | Process step number and timestamp, battery voltage, terminal voltage, auxiliary voltage, charge/discharge current, capacity, energy, operating status |
| Resolution | Voltage setting: 1mV, Voltage display: 0.1mV, Current setting: 1mA, Current display: 0.1mA |
| ESD Protection | Contact discharge ≥ 6KV, Air discharge ≥ 10KV |
| Communication | CAN2.0, communication baud rate 125K/500K |
| Cooling System | Forced air cooling with intelligent fan speed control |
Pessoa de Contato: Mary
Telefone: 13677381316
Fax: 86-0769-89280809